SYSTEM
System settings – section with system settings such as:
- Time zone;
- Storage;
- File names pattern;
- System information sending interval;
- URL of the server that receives system information;
- NTP server settings;
- Setting the device reboot time;
- Ignition sensor settings;
Time
Figure 1 – Time
Table 1 – Parameter Description of Time
Parameter | Parameter Description |
---|---|
Timezone | The time zone that will be set on the device |
DST time shift | The magnitude of the seasonal clock shift |
DST (Summer time)start | Daylight saving time setting |
DST (Winter time) end | Set clock to “winter time |
System maintenance
Figure 2 – section System maintenance
Table 2 – Parameter Description of System maintenance:
Parameter | Parameter Description |
---|---|
Storage file system format | Storage system format in the mNVR can be NTFS or EXT4 |
Delete files policy | The amount of files(in percents) awter which the deletion begins |
Event files count | The number of files after which the deletion begins |
Files disk sharing | disk quota for files - the ratio of event files to loop files |
System reboot | The time when the device will reboot |
Sensor state | On or off ignition sensor and after turning off the ignition and the set time expires the device is turning off |
Timeout | Ignition sensor settings. When meaningful > 0 and no ignition after the specified time interval, the device will turn off. This sensor allows you to connect the device directly to the battery |
Disable IP cameras | Switching off the cameras in the absence of ignition |
Files name pattern
– pattern for setting the name of the created file
Figure 3 – section Files name pattern.
Table 3 – Description of the pattern for setting the name of the created file
Pattern | Pattern description |
---|---|
%% | sign % |
%а | Local abbreviated name of the day of the week (for example, Sun) |
%А | Local full name of the day of the week (for example Monday) |
%b | Local abbreviated name of the month (for example, Jan) |
%B | Local full name of the month (for example, January) |
%c | Local data and time (for example, thur 18 Mar 2021 10:19:29) |
%C | Century; similarly %Y, except for the last two characters (for example, 21) |
%d | Day of a month (for example, 01) |
%D | Date; similarly %m/%d/%y |
%e | Day of a month, supplemented by spaces; similarly %_d |
%F | Full date ; equivalent %Y-%m-%d |
%g | The last two digits of the year, which corresponds to the week number according to ISO 8601 (look %G) |
%G | The year corresponding to the week number in the year according to ISO 8601 (look. %V); usually only makes sense in conjunction with %V |
%h | The same, that %b |
%H | Hour (00..23 |
%I | Hour (01..12) |
%j | The number of a day in year (001..366) |
%k | Hour (0..23) |
%l | Hour (1..12) |
%m | Month (01..12) |
%M | minute (00..59) |
%n | New line |
%N | nanoseconds (000000000..999999999) |
%p | Local equivalent AM or PM; empty if unknown |
%P | similarly %p, but only in lower case |
%r | Local 12-hour time (for example, 11:11:04 PM) |
%R | 24-hour format of hours and minutes; similarly %H:%M |
%s | the number of seconds that elapsed from 1970-01-01 00:00:00 UTC |
%S | second (00..60) |
%t | Tabulation |
%T | time; similarly %H:%M:%S |
%u | Day of the week (1..7); 1 means Monday |
%U | the number of the week in the year that begins on Sunday (00..53) |
%V | week number in the year beginning Monday, according to ISO 8601 (01..53) |
%w | Day of the week (0..6), 0 means Sunday |
%W | week number in the year beginning Monday (00..53) |
%x | Local date display (for example, 31.12.1999) |
%X | Local time display (for example, 23:13:48) |
%y | Last two digits of the year (00..99) |
%Y | Year |
%z | Time zone in format `+hhmm`( for example, -0400) |
%:z | Time zone in format `+hh:mm`( for example, -04:00) |
%::z | Time zone in format `+hh:mm:ss`( for example, -04:00:00) |
%:::z | Часовий пояс з достатньою кількістю двокрапок (наприклад, -04, +05:30) |
%Z | time zone with enough colons (for example, -04, +05:30) |
The next parameters of mNVR are also used.
Table 4 – mNVR settings to customize the name of the file being created
Parameter | Parameter Description |
---|---|
#n | Camera number |
#c | Type of content |
#p | Number of the sensor |
#i | IMEI of the device |
Video files extension – file extension format. MP4 format requires full file download for playback, MKV format supports playback of not fully downloaded files. MKV is recommended for poor communication quality
Servers configuration
Figure 4 – section servers configuration
Table 5 – Parameter Description of servers configuration
Parameter | Parameter Description |
---|---|
URL | The URL of the server that processes and stores system information |
Interval | The interval of sending system information to a given server |
DNS server | IP address of the Internet server |
NTP server | Address and port of the NTP time synchronization server |
PORT | Port number |
Cameras power management using VIN
Figure 5 – Cameras power management using VIN
Table 6 - Cameras power management using VIN parameter description
Parameter | Parameter Description |
---|---|
Power off voltage (8000-32000 mB) | The value of voltage when device is turning off (from 8 to 32V) |
Power on voltage (8000-32000 mB) | The value of voltage when device is turning on (from 8 to 32V) |
Power off time (0-65000 с) | Time at the set voltage after which the device switches off |
Power on time (0-65000 с) | Time at the set voltage after which the device switches on |
To set the default settings, click the Default button. To save settings in NVR click Save settings button.