+ | ====== Installation Recommendations ====== | ||
+ | |||
+ | This section will cover tips on topics such as: | ||
+ | |||
+ | * Unplugging the RJ45 connector | ||
+ | * Unplugging cables that come with the Bi-mNVR device | ||
+ | * Unplugging Bi-mNVR connectors | ||
+ | * Bi-mNVR antennas connection | ||
+ | * Installation highlights | ||
+ | |||
+ | ==== Unplugging the RJ45 connector ==== | ||
+ | |||
+ | There are two ways to pin-up the RJ45 connector: T-568A and T-568B, the pin-up type has no effect on the data rate, so choose the one you like best. **We use the T-568B**. | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | === How to crimp an 8 wire twisted pair === | ||
+ | |||
+ | We need a crimper, an RJ45 connector and a twisted pair, and scissors. | ||
+ | |||
+ | Step 1: Cut the upper sheath at the end of the cable about 2.5 cm from the edge. Next, unwind the twisted wires and take out the excess | ||
+ | |||
+ | Step 2: Clamp the wires between your fingers and line them up. Sort them out as shown in the pictures above | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | Step 3: Shorten the wires so that the wires peek out about 1.5 cm from the edge of the insulation. Use scissors to make a straight cut across all the wires. | ||
+ | |||
+ | Step 4: Carefully insert all 8 wires into the RJ45 connector as far as possible, and make sure they stay aligned and each color goes into the appropriate channel | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | Step 5: Insert the wires all the way into the RJ45 connector, checking the wire sequence. Then insert the connector into the " | ||
+ | |||
+ | ==== Bi-mNVR device pin assignment ==== | ||
+ | |||
+ | * RJ45 connectors, type T568B | ||
+ | |||
+ | ^ No. ^ Name ^ Signal type ^ Pin assignment ^ | ||
+ | | 1 | white-orange | signal | TX+ | | ||
+ | | 2 | orange | signal | TX- | | ||
+ | | 3 | white-green | signal | RX+ | | ||
+ | | 4 | blue | power | +CAM_PWR | | ||
+ | | 5 | white-blue | power | +CAM_PWR | | ||
+ | | 6 | Green | signal | RX- | | ||
+ | | 7 | brown-white | power supply | GND | | ||
+ | | 8 | brown | power | GND | | ||
+ | |||
+ | * CONNECT-BUS connectors | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | No. ^ Name ^ Signal type ^ Pin assignment ^ | ||
+ | | 1 | GND | power | common wire (ground) | | ||
+ | | 2 | CAN L | Input/ | ||
+ | | 3 | + Vin | Power | ' | ||
+ | | 4 | CAN H |Input/ | ||
+ | |||
+ | *CAN port connector | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | ^ No. ^ Name ^ Signal type ^ Pin assignment ^ | ||
+ | | 1 | GND | power | common wire (ground) | | ||
+ | | 2 | TX | Input/ | ||
+ | | 3 | + 3.3V | supply | 3.3V power output | | ||
+ | | 4 | RX | Input/ | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | ^ No. ^ Name ^ Signal type ^ Pin assignment ^ | ||
+ | | 1 | Dat_low 1 | Input | Discrete input with active ' | ||
+ | | 2 | Dat_high 1 | Input | discrete input with active ' | ||
+ | | 3 | + 3.3V | input | analog input | | ||
+ | | 4 | GND | power supply | common wire (ground) | | ||
+ | | 5 | Dat_high 1 | input | discrete input with active ' | ||
+ | | 6 | GND | power supply | common wire (ground) | | ||
+ | |||
+ | ==== General guidelines ==== | ||
+ | |||
+ | === Operating conditions === | ||
+ | |||
+ | * ambient temperature from -30°C to +80°C | ||
+ | * Relative humidity up to 80% at +30°C | ||
+ | * atmospheric pressure between 84 kPa and 107 kPa (630 - 800 mm Hg) | ||
+ | |||
+ | === installation recommendations === | ||
+ | |||
+ | * The device location area should allow for plugging in the connector, excluding the case of its damage, as well as exposure to direct sunlight and moisture | ||
+ | * Recommended mounting location in the vehicle: Under the dashboard, level | ||
+ | |||
+ | === Additional conditions === | ||
+ | |||
+ | * During welding work and vehicle repair it is obligatory to disconnect power connector and peripherals from the device | ||
+ | * Power supply voltage must not exceed 36V. Failure to observe this condition could render the unit inoperable | ||
+ | |||
+ | === Transport and storage conditions === | ||
+ | |||
+ | * The device can be transported in the manufacturer' | ||
+ | * Transportation and storage must be carried out in conditions that meet the storage conditions according to [[https:// | ||
+ | * Permissible level of shock loads: shocks with acceleration of 2-5g with impulse duration of 5-10 ms | ||
+ | * The air of the storage room must not contain aggressive impurities, dust, grease, moisture, exceeding the standards according to. [[https:// | ||
+ | |||
+ | === Safety requirements for installation and maintenance work === | ||
+ | |||
+ | * During work on device installation organizational and technical measures shall be taken, which shall ensure safety of work with measuring equipment, auxiliary equipment and consumables | ||
+ | * The responsibility for observing the safety measures rests with the technical personnel in charge of the device installation, | ||
+ | * On-site compliance with fire safety rules in accordance with [[https:// | ||
+ | * In road transport at the place of work, it is necessary to comply with the requirements of labor safety regulations in accordance with [[https:// | ||
+ | * It is recommended to store the unit in shockproof packaging to avoid damage. | ||
+ | * Before dismantling the unit, the power supply must be switched off. | ||
+ | * Do not install or remove the SIM card while the device is powered | ||
+ | |||